Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38262674

RESUMO

AIMS: Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. METHODS AND RESULTS: Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). CONCLUSION: Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Frequência Cardíaca/fisiologia , Arritmias Cardíacas , Cicatriz/patologia , Ablação por Cateter/métodos
2.
Eur Heart J Cardiovasc Imaging ; 25(2): 188-198, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37819047

RESUMO

AIMS: Conducting channels (CCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular tachycardia (VT). The aim of this work was to study the ability of post-ablation LGE-CMR to evaluate ablation lesions. METHODS AND RESULTS: This is a prospective study of consecutive patients referred for a scar-related VT ablation. LGE-CMR was performed 6-12 months prior to ablation and 3-6 months after ablation. Scar characteristics of pre- and post-ablation LGE-CMR were compared. During the study period (March 2019-April 2021), 61 consecutive patients underwent scar-related VT ablation after LGE-CMR. Overall, 12 patients were excluded (4 had poor-quality LGE-CMR, 2 died before post-ablation LGE-CMR, and 6 underwent post-ablation LGE-CMR 12 months after ablation). Finally, 49 patients (age: 65.5 ± 9.8 years, 97.9% male, left ventricular ejection fraction: 34.8 ± 10.4%, 87.7% ischaemic cardiomyopathy) were included. Post-ablation LGE-CMR showed a decrease in the number (3.34 ± 1.03 vs. 1.6 ± 0.2; P < 0.0001) and mass (8.45 ± 1.3 vs. 3.5 ± 0.6 g; P < 0.001) of CCs. Arrhythmogenic CCs disappeared in 74.4% of patients. Dark core was detected in 75.5% of patients, and its presence was not related to CC reduction (52.2 ± 7.4% vs. 40.8 ± 10.6%, P = 0.57). VT recurrence after one year follow-up was 16.3%. The presence of two or more channels in the post-ablation LGE-CMR was a predictor of VT recurrence (31.82% vs. 0%, P = 0.0038) with a sensibility of 100% and specificity of 61% (area under the curve 0.82). In the same line, a reduction of CCs < 55% had sensibility of 100% and specificity of 61% (area under the curve 0.83) to predict VT recurrence. CONCLUSION: Post-ablation LGE-CMR is feasible, and a reduction in the number of CCs is related with lower risk of VT recurrence. The dark core was not present in all patients. A decrease in VT substrate was also observed in patients without a dark core area in the post-ablation LGE-CMR.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Miocárdio/patologia , Meios de Contraste , Imagem Cinética por Ressonância Magnética/métodos , Cicatriz/patologia , Estudos Prospectivos , Gadolínio , Imageamento por Ressonância Magnética/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/patologia , Espectroscopia de Ressonância Magnética
3.
JACC Clin Electrophysiol ; 9(6): 779-789, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37380313

RESUMO

BACKGROUND: A new functional mapping strategy based on targeting deceleration zones (DZs) has become one of the most commonly used strategies within the armamentarium of substrate-based ablation methods for ventricular tachycardia (VT) in patients with structural heart disease. The classic conduction channels detected by voltage mapping can be accurately determined by cardiac magnetic resonance (CMR). OBJECTIVES: The purpose of this study was to analyze the evolution of DZs during ablation and their correlation with CMR. METHODS: Forty-two consecutive patients with scar-related VT undergoing ablation after CMR in Hospital Clinic (October 2018-December 2020) were included (median age 65.3 ± 11.8 years; 94.7% male; 73.7% ischemic heart disease). Baseline DZs and their evolution in isochronal late activation remaps were analyzed. A comparison between DZs and CMR conducting channels (CMR-CCs) was realized. Patients were prospectively followed for VT recurrence for 1 year. RESULTS: Overall, 95 DZs were analyzed, 93.68% of which were correlated with CMR-CCs: 44.8% located in the middle segment and 55.2% located in the entrance/exit of the channel. Remapping was performed in 91.7% of patients (1 remap: 33.3%, 2 remaps: 55.6%, and 3 remaps: 2.8%). Regarding the evolution of DZs, 72.2% disappeared after the first ablation set, with 14.13% not ablated at the end of the procedure. A total of 32.5% of DZs in remaps correlated with a CMR-CCs already detected, and 17.5% were associated with an unmasked CMR-CCs. One-year VT recurrence was 22.9%. CONCLUSIONS: DZs are highly correlated with CMR-CCs. In addition, remapping can lead to the identification of hidden substrate initially not identified by electroanatomic mapping but detected by CMR.


Assuntos
Desaceleração , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Imageamento por Ressonância Magnética , Coração , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Espectroscopia de Ressonância Magnética
4.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37294671

RESUMO

AIMS: To define a stepwise application of left bundle branch pacing (LBBP) criteria that will simplify implantation and guarantee electrical resynchronization. Left bundle branch pacing has emerged as an alternative to biventricular pacing. However, a systematic stepwise criterion to ensure electrical resynchronization is lacking. METHODS AND RESULTS: A cohort of 24 patients from the LEVEL-AT trial (NCT04054895) who received LBBP and had electrocardiographic imaging (ECGI) at 45 days post-implant were included. The usefulness of ECG- and electrogram-based criteria to predict accurate electrical resynchronization with LBBP were analyzed. A two-step approach was developed. The gold standard used to confirm resynchronization was the change in ventricular activation pattern and shortening in left ventricular activation time, assessed by ECGI. Twenty-two (91.6%) patients showed electrical resynchronization on ECGI. All patients fulfilled pre-screwing requisites: lead in septal position in left-oblique projection and W paced morphology in V1. In the first step, presence of either right bundle branch conduction delay pattern (qR or rSR in V1) or left bundle branch capture Plus (QRS ≤120 ms) resulted in 95% sensitivity and 100% specificity to predict LBBP resynchronization, with an accuracy of 95.8%. In the second step, the presence of selective capture (100% specificity, only 41% sensitivity) or a spike-R <80 ms in non-selective capture (100% specificity, sensitivity 46%) ensured 100% accuracy to predict resynchronization with LBBP. CONCLUSION: Stepwise application of ECG and electrogram criteria may provide an accurate assessment of electrical resynchronization with LBBP (Graphical abstract).


Assuntos
Fascículo Atrioventricular , Terapia de Ressincronização Cardíaca , Humanos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Resultado do Tratamento
5.
Rev. esp. cardiol. (Ed. impr.) ; 76(3): 173-182, mar, 2023. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-216567

RESUMO

Introducción y objetivos La resonancia magnética cardiaca con realce tardío de gadolinio (RMC-RTG) permite la detección no invasiva de la fibrosis auricular izquierda en pacientes con fibrilación auricular (FA). Sin embargo, se desconoce si se puede utilizar la misma metodología en la aurícula derecha (AD). Nuestro objetivo fue definir un umbral estandarizado para caracterizar la fibrosis auricular derecha mediante RMC-RTG. Métodos Se realizaron RMC-RTG de 3 T en 53 personas; se segmentó la AD y se calculó la razón de intensidad de imagen (RII) para la pared de la AD utilizando 1.557.767 píxeles de RII (40.994±10.693 por paciente). El límite superior de la normalidad de la RII (RII promedio+2 desviaciones estándar) se estimó en voluntarios sanos (n = 9); para establecer el umbral de cicatriz densa, se utilizó a los pacientes que se habían sometido previamente a una ablación del flutter auricular típico (n = 9). Se incluyó a pacientes con FA paroxística y persistente (n=10 cada grupo) para la validación. Los valores de RII se correlacionaron con un mapa de voltaje bipolar de alta densidad en 15 pacientes sometidos a ablación de FA. Resultados El límite superior de la normalidad (umbral de fibrosis total) en voluntarios sanos se fijó en RII = 1,21. En el grupo postablación, el 60% del píxel de la RII máximo (umbral de fibrosis densa) se calculó como RII = 1,29. El voltaje bipolar endocárdico mostró una correlación con la RII débil pero significativa. La precisión general entre el mapa electroanatómico y la RMC-RTG para caracterizar la fibrosis fue del 56%. Conclusiones Se determinó una RII > 1,21 como umbral para la detección de fibrosis de la aurícula derecha, mientras que una RII > 1,29 diferencia la fibrosis intersticial de la cicatriz densa. A pesar de las diferencias entre las aurículas izquierda y derecha, se pudo evaluar la fibrosis con RMC-RTG con umbrales similares en ambas cámaras (AU)


Introduction and objectives Late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) allows noninvasive detection of left atrial fibrosis in patients with atrial fibrillation (AF). However, whether the same methodology can be used in the right atrium (RA) remains unknown. Our aim was to define a standardized threshold to characterize RA fibrosis in LGE-CMR. Methods A 3 Tesla LGE-CMR was performed in 53 individuals; the RA was segmented, and the image intensity ratio (IIR) calculated for the RA wall using 1 557 767 IIR pixels (40 994±10 693 per patient). The upper limit of normality of the IIR (mean IIR+2 standard deviations) was estimated in healthy volunteers (n=9), and patients who had undergone previous typical atrial flutter ablation (n=9) were used to establish the dense scar threshold. Paroxysmal and persistent AF patients (n=10 each) were used for validation. IIR values were correlated with a high-density bipolar voltage map in 15 patients undergoing AF ablation. Results The upper normality limit (total fibrosis threshold) in healthy volunteers was set at an IIR = 1.21. In the postablation group, 60% of the maximum IIR pixel (dense fibrosis threshold) was calculated as IIR = 1.29. Endocardial bipolar voltage showed a weak but significant correlation with IIR. The overall accuracy between the electroanatomical map and LGE-CMR to characterize fibrosis was 56%. Conclusions An IIR > 1.21 was determined to be the threshold for the detection of right atrial fibrosis, while an IIR > 1.29 differentiates interstitial fibrosis from dense scar. Despite differences between the left and right atria, fibrosis could be assessed with LGE-CMR using similar thresholds in both chambers (AU)


Assuntos
Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Cicatriz/patologia , Cicatriz/cirurgia , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração/patologia , Imageamento por Ressonância Magnética/métodos
6.
Europace ; 25(3): 989-999, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36607130

RESUMO

AIMS: Heterogeneous tissue channels (HTCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular arrhythmias, but there are few published data about their arrhythmogenic characteristics. METHODS AND RESULTS: We enrolled 34 consecutive patients with ischaemic and non-ischaemic cardiomyopathy who were referred for ventricular tachycardia (VT) ablation. LGE-CMR was performed prior to ablation, and the HTCs were analyzed. Arrhythmogenic HTCs linked to induced VT were identified during the VT ablation procedure. The characteristics of arrhythmogenic HTCs were compared with those of non-arrhythmogenic HTCs. Three patients were excluded due to low-quality LGE-CMR images. A total of 87 HTCs were identified on LGE-CMR in 31 patients (age:63.8 ± 12.3 years; 96.8% male; left ventricular ejection fraction: 36.1 ± 10.7%). Of the 87 HTCs, only 31 were considered arrhythmogenic because of their relation to a VT isthmus. The HTCs related to a VT isthmus were longer [64.6 ± 49.4 vs. 32.9 ± 26.6 mm; OR: 1.02; 95% CI: (1.01-1.04); P < 0.001] and had greater mass [2.5 ± 2.2 vs. 1.2 ± 1.2 grams; OR: 1.62; 95% CI: (1.18-2.21); P < 0.001], a higher degree of protectedness [26.19 ± 19.2 vs. 10.74 ± 8.4; OR 1.09; 95% CI: (1.04-1.14); P < 0.001], higher transmurality [number of wall layers with CCs: 3.8 ± 2.4 vs. 2.4 ± 2.0; OR: 1.31; 95% CI: (1.07-1.60); P = 0.008] and more ramifications [3.8 ± 2.0 vs. 2.7 ± 1.1; OR: 1.59; 95% CI: (1.15-2.19); P = 0.002] than non-arrhythmogenic HTCs. Multivariate logistic regression analysis revealed that protectedness was the strongest predictor of arrhythmogenicity. CONCLUSION: The protectedness of an HTC identified by LGE-CMR is strongly related to its arrhythmogenicity during VT ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Cicatriz/etiologia , Cicatriz/complicações , Meios de Contraste , Gadolínio , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/cirurgia , Miocárdio/patologia , Imageamento por Ressonância Magnética/métodos , Ablação por Cateter/efeitos adversos
7.
Eur Heart J Open ; 3(1): oeac085, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36654964

RESUMO

Aims: With recurrence rates up to 50% after pulmonary vein isolation (PVI) in persistent atrial fibrillation (AF), predictive tools to improve patient selection are needed. Patient selection based on left atrial late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) has been proposed previously (UTAH-classification). However, this approach has not been widely established, in part owed to the lack of standardization of the LGE quantification method. We have recently established a standardized LGE-CMR method enabling reproducible LGE-quantification. Here, the ability of this method to predict outcome after PVI was evaluated. Methods and results: This dual-centre study (n = 219) consists of a prospective derivation cohort (n = 37, all persistent AF) and an external validation cohort (n = 182; 66 persistent, 116 paroxysmal AF). All patients received an LGE-CMR prior to first-time PVI-only ablation. LGE was quantified based on the signal-intensity-ratio relative to the blood pool, applying a uniform LGE-defining threshold of >1.2.  In patients with persistent AF in the derivation cohort, left atrial LGE-extent above a cut-off value of 12% was found to best predict relevant low-voltage substrate (≥2 cm two with <0.5 mV during sinus rhythm) and arrhythmia-free survival 12 months post-PVI. When applied to the external validation cohort, this cut-off value was also predictive of arrhythmia-free survival for both, the total cohort and the subgroup with persistent AF (LGE < 12%: 80% and 76%; LGE > 12%: 55% and 44%; P = 0.007 and P = 0.029, respectively). Conclusion: This dual-centre study established and validated a standardized, reproducible LGE-CMR method discriminating PVI responders from non-responders, which may improve choice of therapeutic approach or ablation strategy for patients with persistent AF.

8.
Europace ; 25(2): 360-365, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36125227

RESUMO

AIMS: Electrical reconnection of pulmonary veins (PVs) is considered an important determinant of recurrent atrial fibrillation (AF) after pulmonary vein isolation (PVI). To date, AF recurrences almost automatically trigger invasive repeat procedures, required to assess PVI durability. With recent technical advances, it is becoming increasingly common to find all PVs isolated in those repeat procedures. Thus, as ablation of extra-PV targets has failed to show benefit in randomized trials, more and more often these highly invasive procedures are performed only to rule out PV reconnection. Here we aim to define the ability of late gadolinium enhancement (LGE)-magnetic resonance imaging (MRI) to rule out PV reconnection non-invasively. METHODS AND RESULTS: This study is based on a prospective registry in which all patients receive an LGE-MRI after AF ablation. Included were all patients that-after an initial PVI and post-ablation LGE-MRI-underwent an invasive repeat procedure, which served as a reference to determine the predictive value of non-invasive lesion assessment by LGE-MRI.: 152 patients and 304 PV pairs were analysed. LGE-MRI predicted electrical PV reconnection with high sensitivity (98.9%) but rather low specificity (55.6%). Of note, LGE lesions without discontinuation ruled out reconnection of the respective PV pair with a negative predictive value of 96.9%, and patients with complete LGE lesion sets encircling all PVs were highly unlikely to show any PV reconnection (negative predictive value: 94.4%). CONCLUSION: LGE-MRI has the potential to guide selection of appropriate candidates and planning of the ablation strategy for repeat procedures and may help to identify patients that will not benefit from a redo-procedure if no ablation of extra-PV targets is intended.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Meios de Contraste , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Gadolínio , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Imageamento por Ressonância Magnética , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
9.
J Interv Card Electrophysiol ; 66(1): 15-25, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35195814

RESUMO

BACKGROUND: Ventricular tachycardia (VT) is caused by the presence of a slow conduction channel (CC) of border zone (BZ) tissue inside the scar-core tissue. Electroanatomic mapping can depict this tissue by voltage mapping. Areas of slow conduction can be detected as late potentials (LPs) and their abolition is the most accepted ablation endpoint. In the current guidelines, bipolar voltage thresholds for BZ and core scar are 1.5 and 0.5 mV respectively. The performance of these values is controversial. The aim of the study is to analyze the diagnostic yield of current amplitude thresholds in voltage map to define VT substrate in terms of CCs of LPs. Predictors of usefulness of current thresholds will be analyzed. METHODS: All patients with structural heart disease who underwent VT ablation in Hospital Clinic in 2016-2017 were included. Maps with delineation of CCs based on LPs were created with contact force sensor catheter. Thresholds were adjusted for every patient based on CCs. Diagnostic yield and predictors of performance of conventional thresholds were analyzed. RESULTS: During study period, 57 consecutive patients were included (age: 60.4 ± 8.5; 50.2% ischemic cardiomyopathy, LVEF 39.8 ± 13.5%). Cutoff voltages that better identified the scar and BZ according to the LP channels were 0.32 (0.02-2 mV) and 1.84 (0.3-6 mV) respectively. Current voltage thresholds identified correctly core and BZ in 87.7% and 42.1% of the patients respectively. Accuracy was worse in non-ischemic cardiomyopathy (NICM) especially for BZ (28.6% vs 55.2%, p = 0.042). CONCLUSIONS: Accuracy of standard voltage thresholds for scar and BZ is poor in terms of LPs detection. Diagnostic yield is worse in NICM patients specially for border zone.


Assuntos
Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Pessoa de Meia-Idade , Idoso , Cicatriz , Lipopolissacarídeos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Isquemia Miocárdica/complicações , Ablação por Cateter/efeitos adversos
10.
Rev Esp Cardiol (Engl Ed) ; 76(3): 173-182, 2023 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35809892

RESUMO

INTRODUCTION AND OBJECTIVES: Late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) allows noninvasive detection of left atrial fibrosis in patients with atrial fibrillation (AF). However, whether the same methodology can be used in the right atrium (RA) remains unknown. Our aim was to define a standardized threshold to characterize RA fibrosis in LGE-CMR. METHODS: A 3 Tesla LGE-CMR was performed in 53 individuals; the RA was segmented, and the image intensity ratio (IIR) calculated for the RA wall using 1 557 767 IIR pixels (40 994±10 693 per patient). The upper limit of normality of the IIR (mean IIR+2 standard deviations) was estimated in healthy volunteers (n=9), and patients who had undergone previous typical atrial flutter ablation (n=9) were used to establish the dense scar threshold. Paroxysmal and persistent AF patients (n=10 each) were used for validation. IIR values were correlated with a high-density bipolar voltage map in 15 patients undergoing AF ablation. RESULTS: The upper normality limit (total fibrosis threshold) in healthy volunteers was set at an IIR = 1.21. In the postablation group, 60% of the maximum IIR pixel (dense fibrosis threshold) was calculated as IIR = 1.29. Endocardial bipolar voltage showed a weak but significant correlation with IIR. The overall accuracy between the electroanatomical map and LGE-CMR to characterize fibrosis was 56%. CONCLUSIONS: An IIR > 1.21 was determined to be the threshold for the detection of right atrial fibrosis, while an IIR > 1.29 differentiates interstitial fibrosis from dense scar. Despite differences between the left and right atria, fibrosis could be assessed with LGE-CMR using similar thresholds in both chambers.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Cicatriz/patologia , Cicatriz/cirurgia , Meios de Contraste , Átrios do Coração/patologia , Imageamento por Ressonância Magnética/métodos , Fibrilação Atrial/cirurgia , Fibrose , Ablação por Cateter/métodos , Gadolínio , Espectroscopia de Ressonância Magnética
11.
JACC Clin Electrophysiol ; 8(11): 1431-1445, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36424012

RESUMO

BACKGROUND: Conduction system pacing (CSP) has emerged as an alternative to biventricular pacing (BiVP). Randomized studies comparing both therapies are scarce and do not include left bundle branch pacing. OBJECTIVES: This study aims to compare ventricular resynchronization achieved by CSP vs BiVP in patients with cardiac resynchronization therapy indication. METHODS: LEVEL-AT (Left Ventricular Activation Time Shortening with Conduction System Pacing vs Biventricular Resynchronization Therapy) was a randomized, parallel, controlled, noninferiority trial. Seventy patients with cardiac resynchronization therapy indication were randomized 1:1 to BiVP or CSP, and followed up for 6 months. Crossover was allowed when primary allocation procedure failed. Primary endpoint was the change in left ventricular activation time, measured using electrocardiographic imaging. Secondary endpoints were left ventricular reverse remodeling and the combined endpoint of heart failure hospitalization or death at 6-month follow-up. RESULTS: Thirty-five patients were allocated to each group. Eight (23%) patients crossed over from CSP to BiVP; 2 patients (6%) crossed over from BiVP to CSP. Electrocardiographic imaging could not be performed in 2 patients in each group. A similar decrease in left ventricular activation time was achieved by CSP and BiVP (-28 ± 26 ms vs -21 ± 20 ms, respectively; mean difference -6.8 ms; 95% CI: -18.3 ms to 4.6 ms; P < 0.001 for noninferiority). Both groups showed a similar change in left ventricular end-systolic volume (-37 ± 59 mL CSP vs -30 ± 41 mL BiVP; mean difference: -8 mL; 95% CI: -33 mL to 17 mL; P = 0.04 for noninferiority) and similar rates of mortality or heart failure hospitalizations (2.9% vs 11.4%, respectively) (P = 0.002 for noninferiority). CONCLUSIONS: Similar degrees of cardiac resynchronization, ventricular reverse remodeling, and clinical outcomes were attained by CSP as compared to BiVP. CSP could be a feasible alternative to BiVP. (LEVEL-AT [Left Ventricular Activation Time Shortening With Conduction System Pacing vs Biventricular Resynchronization Therapy]; NCT04054895).


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco , Bloqueio de Ramo , Doença do Sistema de Condução Cardíaco/terapia , Remodelação Ventricular
12.
J Am Heart Assoc ; 11(20): e026028, 2022 10 18.
Artigo em Inglês | MEDLINE | ID: mdl-36216438

RESUMO

Background Left atrial structural remodeling contributes to the arrhythmogenic substrate of atrial fibrillation (AF), but the role of the right atrium (RA) remains unknown. Our aims were to comprehensively characterize right atrial structural remodeling in AF and identify right atrial parameters predicting recurrences after ablation. Methods and Results A 3.0 T late gadolinium enhanced-cardiac magnetic resonance was obtained in 109 individuals (9 healthy volunteers, 100 patients with AF undergoing ablation). Right and left atrial volume, surface, and sphericity were quantified. Right atrial global and regional fibrosis burden was assessed with validated thresholds. Patients with AF were systematically followed after ablation for recurrences. Progressive right atrial dilation and an increase in sphericity were observed from healthy volunteers to patients with paroxysmal and persistent AF; fibrosis was similar among the groups. The correlation between parameters recapitulating right atrial remodeling was mild. Subsequently, remodeling in both atria was compared. The RA was larger than the left atrium (LA) in all groups. Fibrosis burden was higher in the LA than in the RA of patients with AF, whereas sphericity was higher in the LA of patients with persistent AF only. Fibrosis, volume, and surface of the RA and LA, but not sphericity, were strongly correlated. Tricuspid regurgitation predicted right atrial volume and shape, whereas diabetes was associated with right atrial fibrosis burden; sex and persistent AF also predicted right atrial volume. Fibrosis in the RA was mostly located in the inferior vena cava-RA junction. Only right atrial sphericity is significantly associated with AF recurrences after ablation (hazard ratio, 1.12 [95% CI, 1.01-1.25]). Conclusions AF progression associates with right atrial remodeling in parallel with the LA. Right atrial sphericity yields prognostic significance after ablation.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Ablação por Cateter/métodos , Gadolínio , Átrios do Coração , Fibrose , Espectroscopia de Ressonância Magnética
13.
Front Cardiovasc Med ; 9: 912335, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35979023

RESUMO

Background: Substrate-based ablation has become a successful technique for ventricular tachycardia (VT) ablation. High-density (HD) mapping catheters provide high-resolution electroanatomical maps and better discrimination of local abnormal electrograms. The HD Grid Mapping Catheter is an HD catheter with the ability to map orthogonal signals on top of conventional bipolar signals, which could provide better discrimination of the arrhythmic substrate. On the other hand, conventional mapping techniques, such as activation mapping, when possible, help to identify the isthmus of the tachycardia. Aim: The purpose of this study was to compare clinical outcomes after using two different VT ablation strategies: one based on extensive mapping with the HD Grid Mapping Catheter, including VT isthmus analysis, and the other based on pure substrate ablation. Methods: Forty consecutive patients undergoing VT ablation with extensive HD mapping method in the hospital clinic (November 2018-November 2019) were included. Clinical outcomes were compared with a historical cohort of 26 consecutive patients who underwent ablation using a scar dechanneling technique before 2018. Results: The density of mapping points was higher in the extensive mapping group (2370.24 ± 920.78 vs. 576.45 ± 294.46; p < 0.001). After 1 year of follow-up, VT recurred in 18.4% of patients in the extensive mapping group vs. 34.6% of patients in the historical control group (p = 0.14), with a significantly greater reduction of VT burden: VT episodes (81.7 ± 7.79 vs. 43.4 ± 19.9%, p < 0.05), antitachycardia pacing (99.45 ± 2.29 vs. 33.9 ± 102.5%, p < 0.001), and implantable cardioverter defibrillator (ICD) shocks (99 ± 4.5 vs. 64.7 ± 59.9%, p = 0.02). Conclusion: The use of a method based on extensive mapping with the HD Grid Mapping Catheter and VT isthmus analysis allows better discrimination of the arrhythmic substrate and could be associated with a greater decrease in VT burden.

14.
Pacing Clin Electrophysiol ; 45(9): 1115-1123, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35583311

RESUMO

BACKGROUND: It is unknown whether His-Purkinje conduction system pacing (HPCSP), as either His bundle or left bundle branch pacing, could be an alternative to cardiac resynchronization therapy (BiVCRT) for patients with left ventricular dysfunction needing ventricular pacing due to atrioventricular block. The aim of the study is to compare the echocardiographic response and clinical improvement between HPCSP and BiVCRT. METHODS: Consecutive patients who successfully received HPCSP were compared with a historical cohort of BiVCRT patients. Patients were 1:1 matched by age, LVEF, atrial fibrillation, renal function and cardiomyopathy type. Responders were defined as patients who survived, did not require heart transplantation and increased LVEF ≥5 points at 6-month follow-up. RESULTS: HPCSP was successfully achieved in 92.5% (25/27) of patients. During follow-up, 8% (2/25) of HPCSP patients died and 4% (1/25) received a heart transplant, whereas 4% (1/25) of those in the BiVCRT cohort died. LVEF improvement was 10% ± 8% HPCSP versus 7% ± 5% BiVCRT (p = .24), and the percentage of responders was 76% (19/25) HPCSP versus 64% (16/25) BiVCRT (p = .33). Among survivors, the percentage of patients who improved from baseline II-IV mitral regurgitation (MR) to 0-I MR was 9/11 (82%) versus 2/8 (25%) (p = .02). Compared to those with BiVCRT, patients with HPCSP achieved better NYHA improvement: 1 point versus 0.5 (OR 0.34; p = .02). CONCLUSION: HPCSP in patients with LVEF ≤45% and atrioventricular block improved the LVEF and induced a response similar to that of BiVCRT. HPCSP significantly improved MR and NYHA functional class. HPCSP may be an alternative to BiVCRT in these patients. (Figure 1. Central Illustration). [Figure: see text].


Assuntos
Bloqueio Atrioventricular , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular , Fascículo Atrioventricular , Doença do Sistema de Condução Cardíaco , Estimulação Cardíaca Artificial/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/terapia , Humanos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular/etiologia , Disfunção Ventricular/terapia , Função Ventricular Esquerda
15.
Am J Cardiol ; 174: 53-60, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35437160

RESUMO

Ventricular tachycardia (VT) substrate-based ablation has become the gold standard treatment for patients with structural heart disease-related VT. VT is linked to re-entry in relation to myocardial scarring, with areas of conduction block (core scar) and of slow conduction (border zone). Slow conduction areas can be detected in sinus rhythm as late potentials (LPs). LP abolition has been shown to be the best end point to avoid long-term recurrences. Our study aimed to analyze the challenges of LP abolition and the predictors of failure. We analyzed 169 consecutive patients with structural heart disease (61% ischemic cardiomyopathy, left ventricular ejection fraction: 37 ± 13%) who underwent VT ablation between 2013 and 2018. A preprocedural clinical evaluation, including cardiac magnetic resonance, was done in 66% of patients. Electroanatomical mapping with the identification of LPs was performed in all patients. Noninducibility was achieved in 71% (119), and complete LP abolition was achieved in 61% (103) of patients. Incomplete LP abolition was a powerful predictor of VT recurrence (67% vs 33%, hazard ratio 3.19 [2.1 to 4.7]; p <0.001). Lack of use of a high-density mapping catheter (odds ratio 6.2, 1.2 to 38.1; p = 0.028), the septal substrate (odds ratio 9.34, 2.27 to 38.4; p = 0.002), and larger left ventricular mass (190 ± 58 g vs 156 ± 46 g, p = 0.002) were predictors of incomplete LP abolition. The main reasons that contributed to unsuccessful LP abolition were anatomic obstacles (such as the conduction system) and large extension of the LP area. In conclusion, incomplete LP abolition is related to VT recurrence. Lack of use of a high-density mapping catheter, the septal substrate, and larger left ventricular mass are related to incomplete LP abolition.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Ablação por Cateter/efeitos adversos , Frequência Cardíaca , Humanos , Lipopolissacarídeos , Taquicardia Ventricular/etiologia , Resultado do Tratamento
16.
Pacing Clin Electrophysiol ; 45(3): 374-383, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35015308

RESUMO

BACKGROUND: His-Purkinje conduction system pacing (HPCSP) has been proposed as an alternative to Cardiac Resynchronization Therapy (CRT); however, predictors of echocardiographic response have not been described in this population. Septal flash (SF), a fast contraction and relaxation of the septum, is a marker of intraventricular dyssynchrony. METHODS: The study aimed to analyze whether HPCSP corrects SF in patients with CRT indication, and if correction of SF predicts echocardiographic response. This retrospective analysis of prospectively collected data included 30 patients. Left ventricular ejection fraction (LVEF) was measured with echocardiography at baseline and at 6-month follow-up. Echocardiographic response was defined as increase in five points in LVEF. RESULTS: HPCSP shortened QRS duration by 48 ± 21 ms and SF was significantly decreased (baseline 3.6 ± 2.2 mm vs. HPCSP 1.5 ± 1.5 mm p < .0001). At 6-month follow-up, mean LVEF improvement was 8.6% ± 8.7% and 64% of patients were responders. There was a significant correlation between SF correction and increased LVEF (r = .61, p = .004). A correction of ≥1.5 mm (baseline SF - paced SF) had a sensitivity of 81% and 80% specificity to predict echocardiographic response (area under the curve 0.856, p = .019). CONCLUSION: HPCSP improves intraventricular dyssynchrony and results in 64% echocardiographic responders at 6-month follow-up. Dyssynchrony improvement with SF correction may predict echocardiographic response at 6-month follow-up.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Estimulação Cardíaca Artificial , Terapia de Ressincronização Cardíaca/métodos , Ecocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração , Humanos , Estudos Retrospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/prevenção & controle , Função Ventricular Esquerda
17.
Pacing Clin Electrophysiol ; 45(1): 72-82, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34820857

RESUMO

AIMS: Neither the long-term development of ablation lesions nor the capability of late gadolinium enhancement (LGE)-MRI to detect ablation-induced fibrosis at late stages of scar formation have been defined. We sought to assess the development of atrial ablation lesions over time using LGE-MRI and invasive electroanatomical mapping (EAM). METHODS AND RESULTS: Ablation lesions and total atrial fibrosis were assessed in serial LGE-MRI scans 3 months and >12 months post pulmonary vein (PV) isolation. High-density EAM performed in subsequent repeat ablation procedures served as a reference. Serial LGE-MRI of 22 patients were analyzed retrospectively. The PV encircling ablation lines displayed an average LGE, indicative of ablation-induced fibrosis, of 91.7% ± 7.0% of the circumference at 3 months, but only 62.8% ± 25.0% at a median of 28 months post ablation (p < 0.0001). EAM performed in 18 patients undergoing a subsequent repeat procedure revealed that the consistent decrease in LGE over time was owed to a reduced detectability of ablation-induced fibrosis by LGE-MRI at time-points > 12 months post ablation. Accordingly, the agreement with EAM regarding detection of ablation-induced fibrosis and functional gaps was good for the LGE-MRI at 3 months (κ .74; p < .0001), but only weak for the LGE-MRI at 28 months post-ablation (κ .29; p < .0001). CONCLUSION: While non-invasive lesion assessment with LGE-MRI 3 months post ablation provides accurate guidance for future redo-procedures, detectability of atrial ablation lesions appears to decrease over time. Thus, it should be considered to perform LGE-MRI 3 months post-ablation rather than at later time-points > 12 months post ablation, like for example, prior to a planned redo-ablation procedure.


Assuntos
Fibrilação Atrial/cirurgia , Cicatriz/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Cicatriz/etiologia , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose/diagnóstico por imagem , Fibrose/etiologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Estudos Retrospectivos , Espanha
18.
JACC Clin Electrophysiol ; 7(11): 1400-1409, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34217660

RESUMO

OBJECTIVES: This study hypothesized that the shorter intrinsic PR interval observed in women allows a greater degree of fusion with intrinsic conduction, achieving a shorter QRS interval duration and, thus, a better response. BACKGROUND: Women benefit more from cardiac resynchronization therapy (CRT) than men. However, the reason for this difference remains elusive. METHODS: A cohort of 180 patients included in the BEST (Fusion based optimization in resynchronization therapy [ECG Optimization of CRT: Evaluation of Mid-Term Response]; NCT01439529) study were retrospectively analyzed. Patients were initially randomized to either nonoptimized CRT (NON-OPT group; n = 89) or electrocardiographically optimized CRT based on the fusion-optimized intervals (FOI) method (FOI group; n = 91). Echocardiographic response was defined as a >15% decrease in left ventricular end-systolic volume at the 12-month follow-up. RESULTS: The basal PR interval was shorter in women as compared to men. In the NON-OPT group, CRT resulted in a shorter paced QRS interval in women than in men (134 ± 21 ms vs. 151 ± 21 ms, respectively; p = 0.003, 95% confidence interval [CI]: -27 to -5.6) and better response in women than in men: 70.4% vs. 46.4%, respectively (odds ratio: 0.37; p = 0.04; 95% CI: 0.14 to 0.97). There were no differences in paced QRS interval duration (126 ± 13 ms vs. 129 ± 17 ms; p = 0.47) or response between women and men in the FOI group (68% vs. 70.5%; odds ratio: 1.12; p = 0.82; 95% CI: 0.41 to 3.07). FOI extended the atrioventricular interval to obtain the best fusion; the atrioventricular intervals tended to require greater extension in men than in women (22 ± 33 ms vs. 8 ± 28 ms, respectively; p = 0.07). CONCLUSIONS: Women had a shorter PR interval, which was associated with a shorter QRS interval and better response to CRT. The difference in QRS interval duration and response between men and women did not persist when CRT was optimized using fusion with intrinsic conduction (FOI programming).


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Dispositivos de Terapia de Ressincronização Cardíaca , Feminino , Insuficiência Cardíaca/terapia , Frequência Cardíaca , Humanos , Masculino , Estudos Retrospectivos
19.
Europace ; 23(9): 1437-1445, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-34142121

RESUMO

AIMS: Ventricular tachycardia (VT) substrate-based ablation has an increasing role in patients with structural heart disease-related VT. VT is linked to re-entry in relation to myocardial scarring with areas of conduction block (core scar) and areas of slow conduction [border zone (BZ)]. VT substrate can be analysed by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Our study aims to analyse the role of LGE-CMR in identifying predictors of VT recurrence after ablation. METHODS AND RESULTS: We analysed 110 consecutive patients who underwent VT ablation from 2013 to 2018. All patients underwent a preprocedural LGE-CMR, and in 94 patients (85.5%), the CMR was used to aid the ablation. All LGE-CMR images were semi-automatically processed using dedicated software to detect scarring and conducting channels. After a median follow-up of 2.7 ± 1.6 years, the overall VT recurrence was 41.8% with an implantable cardioverter-defibrillator shock reduction from 43.6% to 28.2% before and after ablation, respectively. The amount of BZ (26.6 ± 13.9 vs. 19.6 ± 9.7 g, P = 0.012), the total amount of scarring (37.1 ± 18.2 vs. 29 ± 16.3 g, P = 0,033), and left ventricular (LV) mass (168.3 ± 53.3 vs. 152.3 ± 46.4 g, P < 0.001) were associated with VT recurrence. LGE septal distribution [62.5% vs. 37.8%; hazard ratio (HR) 1.67 (1.02-3.93), P = 0.044], channels with transmural path [66.7% vs. 31.4%, HR 3.25 (1.70-6.23), P < 0.001], and midmural channels [54.3% vs. 27.6%, HR 2.49 (1.21-5.13), P = 0.013] were related with VT recurrence. Multivariate analysis showed that the presence of septal LGE [HR 3.67 (1.60-8.38), P = 0.002], transmural channels [HR 2.32 (1.15-4.72), P = 0.019], and LV mass [HR 1.01 (1.005-1.019), P = 0.002] were independent predictors of VT recurrence. CONCLUSION: Pre-procedural LGE-CMR is a helpful and feasible technique to identify patients with high risk of VT recurrence after ablation. LV mass, septal LGE distribution, and transmural channels were predictive factors of post-ablation VT recurrence.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Recidiva , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia
20.
Europace ; 23(10): 1559-1567, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-33975341

RESUMO

AIMS: Left atrial (LA) fibrosis is present in patients with atrial fibrillation (AF) and can be visualized by magnetic resonance imaging with late gadolinium enhancement (LGE-MRI). Previous studies have shown that LA fibrosis is not randomly distributed, being more frequent in the area adjacent to the descending aorta (DAo). The objective of this study is to analyse the relationship between fibrosis in the atrial area adjacent to the DAo and the distance to it, as well as the prognostic implications of this fibrosis. METHODS AND RESULTS: Magnetic resonance imaging with late gadolinium enhancement was obtained in 108 patients before AF ablation to analyse the extent of LA fibrosis and the distance DAo-to-LA. A high-density electroanatomic map was performed in a subgroup of 16 patients to exclude the possibility of an MRI artifact. Recurrences after ablation were analysed at 1 year of follow-up. The extent of atrial fibrosis in the area adjacent to the DAo was inversely correlated with the distance DAo-to-LA (r = -0.34, P < 0.001). This area had the greatest intensity of LGE [image intensity ratio (IIR) 1.14 ± 0.15 vs. 0.99 ± 0.16; P < 0.001] and also the lowest voltage (1.07 ± 0.86 vs. 1.54 ± 1.07 mV; P < 0.001) and conduction velocity (0.65 ± 0.06 vs. 0.96 ± 0.57 mm/ms; P < 0.001). The extent of this regional fibrosis predicted recurrence after AF ablation [hazard ratio (HR) 1.02, 95% CI 1.01-1.03; P = 0.01], however total fibrosis did not (HR = 1.01, 95% CI 0.97-1.06, P = 0.54). CONCLUSIONS: Atrial fibrosis was predominantly located in the area adjacent to the DAo, and increased with the proximity between the two structures. Furthermore, this regional fibrosis better predicted recurrence after AF ablation than total atrial fibrosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/patologia , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , Prognóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...